Cylinder Fill Limit Reason

As found on Clyinder Fill Limit Reason monitor


ValueReason
0Standard Limitation
1Condensante
2ATL Component Protection
3HDP Control Limit
4EKP Funding (Electric Fuel pump, In-Tank Lift Pump) overall fuel demand and over temp status from fuel volume.  EFP Load limit tables can be tweaked to adjust
5Trans KR Driving behavior
6ATM Component Protection Controller
7Particulate Filter
8Injection duration out of the window to inject enough fuel


Torque Limit State

As seen on Torque Limitation State monitor.

Bit PositionDec.HexDescription
011ASR Limitation through Anti-Slip Control (Torque Reduction
122MSR Limitation by engine drag control (Torque Increase)
244GS_DEC Transmission intervention
388GS_INC Transmission Intervention
41610NREG_DEC Speed Control
53220NREG_INC Speed Control
66440DCC_INC Longitudinal Dynamics management (Cruise Control etc.)
712880SELFSTABAB operating losses
8256100Fuel Temperature Limit
9512200COOLING Limitation in cooling
101024400VAR_UL Limit UL Variant
112048800NMAX Limitation Nmax
1240961000

VMAX torque limitation through speed limitation

1381922000ACC_CTL Fusi A regulation
14163844000PARKING BRAKE Parking brake
15327688000HA_DIF rear axle gear protection
166553610000EMERGENCY RUNNING MANAGER Limitation by emergency running manager
1713107220000MD_RF Limitation by filling limitation RF avoids an imbalance between torque and load requests
1826214440000MD_MOTOR Limitation by motor protection
1952428880000SLAVE_STG limitation of 2nd control unit
201048576100000GS_PERM guided gear protection
212097152200000MD_RAD Breaking load drive axle
224194304400000GS_AUTARK self-sufficient gearbox protection
238388608800000KUPPLUNGSSHUTZ_HS Coupling protection HS
2416777216100000BEGRENZUNG_GHAS controlled rear axle lock

Contact Us:

EcuTek Technical Support

support@ecutek.com

(+44) 1895 811200

When dialing from within the UK, the country code is not required so dial 01895 811200


Open Hours

Monday to Friday 9:00am - 5:00pm BST (UK Time)

(4am-1230pm Eastern Standard TIme US)

Visitors by appointment only


EcuTek Tehnologies Ltd.
8 Union Buildings
Wallingford Road
Uxbridge, UB8 2FR
England

VAT No: 
GB 235 2616 23

  • No labels